This 48V 200Ah lithium iron phosphate battery is perfect in many different marine applications. It maintains consistent power and is equipped with an M10 terminal type and built-in overcharge protection. All RELiON LiFePO4 batteries have installation flexibility, fast-charging capabilities and are maintenance free.
After snowmobiling, fishing or relaxing on the lake in the scenic Superior National Forest in northern Minnesota, the last thing the Schumann family wanted to do was worry about whether they’d have power when they arrived back at their off-grid cabin. The Schumanns also wanted to enjoy peace and quiet in nature and not have to constantly listen to a noisy, polluting generator that diminishes the experience of being at their cabin in the middle of the forest. After nearly eight months of struggling to maintain power in their cabin by charging their absorbed glass mat (AGM) lead-acid batteries with a generator, the Schumanns had gone through two sets of failed lead-acid batteries and knew they needed to find a better solution.
Keep ReadingElectrical Specifications |
|
---|---|
Nominal Voltage | 51.2 V |
Nominal Capacity | 200 Ah |
Capacity @ 25A | 480 min |
Energy | 10.24 kWh |
Resistance | 50 mΩ @ 50% SOC |
Efficiency | 99% |
Self Discharge | <3% per Month |
Maximum Modules in Series | 1 (Single Use) |
Mechanical Specifications |
|
---|---|
Dimensions (L x W x H) | 34.3 x 14.2 x 15.6” |
867 x 358 x 393 mm | |
Weight | 302 lbs (137 kg) |
Terminal Type | M10 x 1.5 |
Terminal Torque | 110 - 125 in-lbs (12.2 - 14 N-m) |
Case Material | Steel Case |
Enclosure Protection | IP65 |
Cell Type - Chemistry | Cylindrical - LiFePO4 |
Discharge Specifications |
|
---|---|
Maximum Continuous Discharge Current | 200 A |
Peak Discharge Current | 250 A (4 s ±1 s) |
BMS Discharge Current Cut-Off | 390 A (5 s) |
Recommended Low Voltage Disconnect | 44 V |
BMS Discharge Voltage Cut-Off | 40 V (2.5 ±0.1 vpc) |
Reconnect Voltage | 40.5 V (2.53 ±0.1 vpc) |
Short Circuit Protection | 5% |
Charge Specifications |
|
---|---|
Recommended Charge Current | 10 A - 100 A |
Maximum Charge Current | 200 A |
Charge Current 32ºF to 14ºF (0 to -10 ºC) | ≤0.1 C |
Charge Current -4ºF to 14ºF (-20 to -10 ºC) | ≤0.05 C |
Recommended Charge Voltage | 56.0 V - 58.4 V |
BMS Charge Voltage Cut-Off | 60.8 V (3.8 ±0.025 vpc) |
(1.0 ±0.3 s) | |
Reconnect Voltage | 60.8 V (3.9 vpc) |
Balancing Voltage | 60.3 V (3.87 vpc) |
Temperature Specifications |
|
---|---|
Discharge Temperature | -4 to 131 ºF (-20 to 55 ºC) |
Charge Temperature* | -4 to 131 ºF (-20 to 55 ºC) |
Storage Temperature | 23 to 95 ºF (-5 to 35 ºC) |
BMS High Temperature Cut-Off | 149 ºF (65 ºC) |
Reconnect Temperature | 145 ºF (63 ºC) |
*Refer to charge currents below 0°C (32°F) |
Compliance Specifications |
|
---|---|
Certifications | CE (battery) |
UL1642 & IEC62133 (cells) | |